
NTC Thermistor Excel Calculator: Beta Formula & Limits
Use a manufacturer’s resistance-temperature (R/T) data to convert an NTC thermistor reading into temperature. A basic Excel worksheet can implement the Beta equation when the sensor’s nominal resistance, reference temperature and Beta value are known. The equation is an approximation: do not treat a generic spreadsheet as a universal calculator for every thermistor. Inputs to collect from the datasheet R₀: nominal resistance at the reference temperature. T₀: the reference temperature, converted to kelvin for calculation. B: Beta value in kelvin, with its specified temperature interval. R: measured thermistor resistance, expressed in the same unit as R₀. Do not assume that








